文章摘要
朱翔,汪宣,徐继俊,徐文君,沈建敏,蓝闽波,赵红莉.三维多孔碳纳米材料用于烟用纸张中五氯苯酚的测定方法研究[J].包装工程,2023,44(3):224-232.
ZHU Xiang,WANG Xuan,XU Ji-jun,XU Wen-jun,SHEN Jian-min,LAN Min-bo,ZHAO Hong-li.Determination of Pentachlorophenol in Cigarette Paper Using Three-dimensional Porous Carbon Nanomaterials[J].Packaging Engineering,2023,44(3):224-232.
三维多孔碳纳米材料用于烟用纸张中五氯苯酚的测定方法研究
Determination of Pentachlorophenol in Cigarette Paper Using Three-dimensional Porous Carbon Nanomaterials
  
DOI:10.19554/j.cnki.1001-3563.2023.03.028
中文关键词: 烟用纸张  三维多孔碳纳米材料  电化学传感器  五氯苯酚  检测/监测
英文关键词: cigarette paper  three-dimensional porous carbon nanomaterials  electrochemical sensor, pentachlorophenol  determination/monitoring
基金项目:上海烟草集团有限责任公司科技项目(K2017–001);上海烟草包装印刷有限公司科技项目(K2021–006)
作者单位
朱翔 上海烟草包装印刷有限公司 技术中心上海 200137 
汪宣 上海烟草包装印刷有限公司 技术中心上海 200137 
徐继俊 上海烟草包装印刷有限公司 技术中心上海 200137 
徐文君 上海烟草包装印刷有限公司 技术中心上海 200137 
沈建敏 上海烟草包装印刷有限公司 技术中心上海 200137 
蓝闽波 华东理工大学上海 200237 
赵红莉 华东理工大学上海 200237 
摘要点击次数:
全文下载次数:
中文摘要:
      目的 建立烟用纸张中五氯苯酚(PCP)的快速电化学测定方法。方法 基于沸石咪唑酯骨架(ZIF)的ZIF–8、ZIF–67具有相同的晶胞参数和同构性,以ZIF–8@ZIF–67为模板制备三维纳米多孔碳(NGPC)。利用NGPC的高比表面积以及优异的电子传递效率构建的传感器(记作NGPC/SPCE)对PCP具有很好的响应。结果 在0.86 V的检测电位下,NGPC/SPCE具有较高的灵敏度(2.452 µA.cm−2.L.mg−1)。传感器对PCP的检测具有良好的选择性。传感器对PCP检测具有较好的准确度和精密度。3个浓度梯度的回收率为95.7~98.6;6次测试结果的相对标准偏差为2.07%。传感器对PCP的检测具有较好的长期稳定性。同一传感器连续检测25 d后,仍保持原先88.1%的响应。结论 文中构建的传感器适用于对烟用纸张中PCP的检测,并能获得理想的检测结果。
英文摘要:
      The work aims to develop a rapid electrochemical determination method of pentachlorophenol (PCP) in cigarette paper. Based on the same unit cell parameters and isomorphism of ZIF-8 and ZIF-67, the three-dimensional nanoporous carbon (NGPC) was prepared with ZIF-8@ZIF-67 as a template. Considering the advantage of the large specific surface area and high electron transfer efficiency of NGPC, the constructed sensor (named NGPC/SPCE) had a good response to PCP. At the detection potential of 0.86 V, the sensor had a high sensitivity (2.452 µA.cm−2.L.mg−1) with good selectivity. Besides, the sensor possessed good accuracy and precision for detection of PCP. The recovery results of the three concentration gradients were between 95.7%-98.6%. Additionally, the relative standard deviation of the six consecutive test results was 2.07%. The sensor had good long-term stability for detection of PCP. After 25 days of continuous detection, the sensor can still maintain 88.1% of the initial sensitivity. Thus, the sensor developed in the work is suitable for detection of PCP in cigarette paper with a satisfactory result.
查看全文   查看/发表评论  下载PDF阅读器
关闭

关于我们 | 联系我们 | 投诉建议 | 隐私保护 | 用户协议

您是第21518746位访问者    渝ICP备15012534号-2

版权所有:《包装工程》编辑部 2014 All Rights Reserved

邮编:400039 电话:023-68795652 Email: designartj@126.com

    

渝公网安备 50010702501716号