基于测量不确定度分析检测过程中关键控制点
Critical Control Points in Analysis and Detection Process Based on Measurement Uncertainty
投稿时间:2020-07-02  
DOI:10.19554/j.cnki.1001-3563.2020.21.021
中文关键词: 测量不确定度  增塑剂迁移  关键控制点  食品接触材料
英文关键词: uncertainty of measurement  migration of plasticizer  critical control point  food contact material
基金项目:广东省普通高校青年创新人才项目(自然科学)(2017GkQNCX010);国家重点研发计划子任务(2018YFD0701002);广东省省级(基础研究及应用研究重大)项目(2016KZDXM028);广东省科技计划(2017B020206005);广东省重点领域研发计划(2019B020225001)
作者单位
张丽霞 华南农业大学 食品学院广州 510000
清远海关综合技术服务中心广东 清远 511515 
毛秋媚 清远海关综合技术服务中心广东 清远 511515 
陈秋菊 清远食品检验中心广东 清远 511515 
郭汉城 清远海关综合技术服务中心广东 清远 511515 
摘要点击次数:
全文下载次数:
中文摘要:
      目的 通过测量不确定度的评定,分析食品接触材料中增塑剂测定过程的关键控制点。方法 采用气相色谱-质谱法测定食品接触材料塑料杯中增塑剂邻苯二甲酸二己酯(DEHP)在50%(体积分数)乙醇模拟溶液、60 ℃水浴温度和1 h迁移时间环境下的迁移量,评估和量化检测过程中的各不确定度因素。结果 在检测过程中,对测量不确定度贡献较大的因素为样品均匀性、检测仪器重复性和迁移时水浴温度的波动,三者的相对标准不确定度分别为9.55×10−2,5.67×10−2和4.58×10−2。结论 分析食品接触材料中增塑剂测定过程关键控制点样品的均匀性及检测仪器的重复性,以3组平行试验为宜,浸泡用电热恒温水浴锅的温度波动需控制在±1.0 ℃。通过严格把控各关键控制点,以确保增塑剂测定结果的准确度和精密度。
英文摘要:
      The work aims to analyze the critical control points in determination of plasticizer migration from food contact materials though evaluating the uncertainty of measurement. Under the condition of 50% (volume fraction) ethanol of simulated solution, 60 ℃ of the bath temperature and 1 h immersion time, the gas chromatography-mass spectrometry (GC-MS) was employed to determine the migration of the plasticizer dioctyl phthalate (DEHP) in the plastic cup, which belongs to contact materials. Moreover, the uncertainty factors in the detection process were evaluated and quantified. The major factors contributing to the measurement uncertainty in the detection process were the sample uniformity, the repeatability of the detection instrument and the fluctuation of bath temperature during migration. The relative standard uncertainty of the three factors were 9.55×10−2, 5.67×10−2 and 4.58×10−2, respectively. The uniformity of the sample and repeatability of the testing instrument should be carried out in three parallel tests, and temperature fluctuation allowance of the electric thermostatic water bath pot used for detection should be ±1.0 °C. Each critical control points, should be controlled strictly to guarantee the accurate and precise determination result of plasticizer.