文章摘要
李英,李成发,孙小颖,陈旭辉,陈枝楠,苏丹,吴绍精.气相色谱法测定食品接触材料中12种单体的迁移量[J].包装工程,2015,36(11):36-41,50.
LI Ying,LI Cheng-fa,SUN Xiao-ying,CHEN Xu-hui,CHEN Zhi-nan,SU Dan,WU Shao-jing.Determination of Migration of 12 Monomers in Plastic Food Contact Materials by Gas Chromatography[J].Packaging Engineering,2015,36(11):36-41,50.
气相色谱法测定食品接触材料中12种单体的迁移量
Determination of Migration of 12 Monomers in Plastic Food Contact Materials by Gas Chromatography
投稿时间:2014-12-10  修订日期:2015-06-10
DOI:
中文关键词: 有毒有害单体  迁移量  食品接触材料  顶空气相色谱法
英文关键词: poisonous and harmful monomers  migration amount  food contact materials  headspace gas chromatography
基金项目:“十二五” 科技支撑计划 (2011BAK10B05-03)
作者单位
李英 深圳出入境检验检疫局深圳 518067 
李成发 深圳出入境检验检疫局深圳 518067 
孙小颖 深圳出入境检验检疫局深圳 518067 
陈旭辉 深圳出入境检验检疫局深圳 518067 
陈枝楠 深圳检验检疫科学研究院深圳 518067 
苏丹 深圳出入境检验检疫局深圳 518067 
吴绍精 深圳检验检疫科学研究院深圳 518067 
摘要点击次数:
全文下载次数:
中文摘要:
      目的 建立同时测定食品接触材料中 12 种丙烯酸酯和甲基丙烯酸酯类单体迁移量的分析方法。 方法 采用水、 乙酸(质量分数为3%)、 乙醇(体积分数为10%)和橄榄油浸泡食品接触材料, 将得到的水、 乙酸、 乙醇等水性模拟物和橄榄油模拟物分别经过 80, 90 ℃顶空加热 20 min 后, 通过DB-624石英毛细管柱(30 m×0.32 mm×1.8 μm)分离, 顶空进样分析, 氢火焰离子化检测器检测, 保留时间定性, 峰面积定量。结果 12种单体在0.1~50 mg/L(水性模拟物)及0.5~50 mg/kg(橄榄油模拟物)的浓度范围内呈良好线性, 相关系数 R大于0.999。加标回收率为89.3%~109.6%, 相对标准偏差为1.13%~7.55%。结论 该方法前处理简便, 分离度好, 分析灵敏度高, 满足食品接触材料中12种丙烯酸酯和甲基丙烯酸酯类单体迁移量的分析要求。
英文摘要:
      This experiment established an effective analytical method for the simultaneous determination of the migration amount of 12 ester monomers including acrylic esters and metacrylic acid esters in food contact materials by gas chromatography (GC). Using water, 3% acetic acid, 10% ethanol and olive oil soaked food contact materials, the obtained aqueous food simulants (water, 3% acetic acid, 10% ethanol) and olive oil simulant were treated at 80 ℃ and 90 ℃ respectively for 20 min, then separated on a DB-624 column (30 m×0.32 mm×1.8 μm) for headspace injection analysis with hydrogen flame ionization detector for qualitation by time retention and quantitation by peak area. The results showed a good linear correlation in the range of 0.05~10 mg/L (aqueous food simulants) and 0.1~50 mg/kg (olive oil simulant) with correlation coefficients above 0.999. The recovery of the ester compounds spiked in the sample and the relative standard deviation were 89.3% ~109.6% and 1.13% ~7.55% respectively. The method was simple with good separation and high analytical sensitivity, and met the analysis requirements of migration of the 12 acrylate monomers in food contact materials.
查看全文   查看/发表评论  下载PDF阅读器
关闭

关于我们 | 联系我们 | 投诉建议 | 隐私保护 | 用户协议

您是第21243292位访问者    渝ICP备15012534号-2

版权所有:《包装工程》编辑部 2014 All Rights Reserved

邮编:400039 电话:023-68795652 Email: designartj@126.com

    

渝公网安备 50010702501716号